Summary
Overview
Work History
Education
Skills
Websites
Extra Skills
Interests
Pertinent Information
Additional Information
Certification
Timeline
Generic
Roland Niñal Traña

Roland Niñal Traña

Registered Electrical Engineer I Registered Master Electrician I BOSH Safety Officer
Digos City

Summary

Experienced Electrical Engineer specializing in power distribution and renewable energy, with a focus on photovoltaic power plants. Proven track record in operations management, maintenance, and resolving complex system issues. Proficient in MS Office, people management, and communication. Committed to ongoing professional development in the industry.

Overview

6
6
years of professional experience
5
5
years of post-secondary education
12
12
Certifications
4
4
Languages

Work History

Inverter Engineer (INGECON SUN 920TL X 360 Volts)

AlterPower Digos Solar, Inc.
06.2022 - 04.2025
  • Operated and maintained 27 units of central inverters manufactured in Spain (24.759 MWp-AC Capacity in total with eight SCB inputs) in a 28.5 MWp-DC solar power plant (92,232 pcs of 310-watt polycrystalline PV panels), the largest Photovoltaic Plant in Mindanao.
  • Demonstrated proficiency in understanding the Ingeteam SUN 920 TL (360V output) outdoor central inverter from scratch, despite limited knowledge transfer due to the previous inverter engineer's abrupt relocation to Australia. Assumed the role after promotion and independently mastered system operations.
  • Developed a comprehensive Excel dashboard to monitor key performance metrics, including Capacity Factor, Generation (kWh), Inverter/Grid Availability, Plant Available Capacity, Inverter Activities, Material Inventory, Weather Status/Forecast, Daily Inverter Data, Budget Proposals, Nodal Monitoring, Spare Usage Tracking, Monthly/Yearly Summary Reports, Interactive graphics for alarm monitoring across 27 inverters.
  • Identified and resolved 14 out of 25 malfunctioning nodes (when I assumed the role) through root-cause analysis, significantly improving year-to-date generation efficiency.
  • Drove consistent Year-to-date generation growth (Achieved this despite in year 2024, there are more nodes being offline than in 2023, underscoring commitment to system reliability and operational efficiency. YEAR 2022: 31,793,430 kWh, YEAR 2023: 42,742,407 kWh, YEAR 2024 (under tenure): 40,351,446 kWh.
  • Successfully resolved 508 inverter alarms, including critical issues such as: 0003H: Grid frequency/voltage out of spec (12 instances), 7FFFH: Consecutive branch faults/contactor errors (127 instances), 0040H: Hardware faults (ADC errors, LVRT kit issues) (57 instances), 0100H: Current range/AC protector faults (5 instances), 0200H: DC fuse/arrester failures (72 instances), 8000H: Low-voltage shutdowns (21 instances), 1000H: Manual shutdown due to the emergency push-button, the display or communications or a badly closed door on the unit (119 instances), 4000H: High DC input voltage (3 instances), composite faults (0240H, 0340H, 0303H, 2240H, 1300H, 0210H) (92 instances).
  • Conducted preventive and corrective maintenance, including HVAC filter replacement, inverter cleaning, and re-torquing.
  • Collaborated with cross-functional teams to enhance system performance.
  • Ensured efficient operations of a 28.59 MW DC solar farm, expected to expand to 40 MW.
  • Proficient in analyzing key solar PV performance metrics, including Reference Yield, Array Yield, Final Yield, Performance Ratio (PR), Capacity Utilization Factor (CUF), PV Module Efficiency, Inverter Efficiency, System Efficiency, and Inverter Loading Ratio (ILR).
  • Delivered 42,742,407 kWh to the NGCP Matan-ao Substation without curtailment, surpassing the budgeted 41,854,189 kWh by 2.12%-demonstrating effective grid integration and operational efficiency.
  • Achieved Year-to-Date (YTD) Performance: 20.09% Capacity Factor, 99.33% Inverter Availability, 98.82% Grid Availability, 99.50% Plant Available Capacity.
  • Maintained 3.18% Year-to-Date forecast error accuracy for Intraday Renomination vs. Day-Ahead forecasts, meeting IEMOP's 15-minute real-time dispatch requirements for WESM (Wholesale Electricity Spot Market).
  • Conducted routine inspections and maintained plant equipment integrity.
  • Employed occupational safety and health standards for safe operations.
  • Performed safety inspections and monitored contractor performance.
  • Conducted transmission line foot patrols and 69-KV equipment thermal scanning.
  • Created equipment checklists and spare parts inventory templates.
  • Able to understand the concepts of Testing and Commissioning and Design and Installation Process of the Photovoltaic Plant.

SAP Technology Consultant

DXC Technology
03.2021 - 11.2021
  • Delivered assigned tasks within the project delivery cycle.
  • Configured systems, troubleshot errors, monitored performance, and contributed to technical solution designs.

Project Staff Engineer

Davao Light and Power Company
02.2019 - 07.2020
  • Ensured timely execution of project implementation.
  • Collaborated with contractors to meet design standards on-site.
  • Managed material forecasting, auditing, and quality control of line hardware.
  • Coordinated with various departments for material storage, procurement, and logistics.
  • Gained foundational knowledge of distribution systems.
  • Optimized inventory management, reducing waste and ensuring availability of key supplies.

Education

Bachelor of Science - Electrical Engineering

University of Southeastern Philippines
BO. Obrero, Davao City
04.2012 - 06.2017

Skills

  • Renewable Energy
  • Operations and Maintenance
  • Troubleshooting Electrical Systems
  • Proficient in MS Office
  • Proficient in Google Apps
  • PVSyst
  • Basic SCADA Operation

  • Basic ETAP
  • Basic CAD
  • Basic SketchUp
  • Problem-solving
  • Team Leadership
  • Communication

Extra Skills

  • Singing
  • Dancing
  • Essay Writing
  • Extemporaneous Speaking
  • Smart Talking

Interests

Design Thinking
Management
Teaching
Charity Volunteering
Music
Books
Society
Politics

Pertinent Information

Pertinent Information

SSS NO: 09-4182284-2

Philhealth NO: 16-251107852-0

PAG-IBIG NO: 1212-2732-6156

TIN NO: 347178470-0000

Driver’s License: M16-19-007472

Passport No: P9433662B

Additional Information

Engr. Ronald B. Nefalar, REE

Hexa Philippines Holdings, Inc.

Operations and Maintenance Manager

0930 210 6214


Engr. Jose Margo Mananquil, REE, MIB

Alternergy Phil Holdings Corp / NCP

Senior Manager

0917 898 4294


Engr. Rapha Julysses E. Perez, MSc ECS

University of the Philippines – Mintal,
Davao City
Instructor

0961 528 0937

Certification

Registered Electrical Engineer, Professional Regulation Commission, Philippines

Timeline

Inverter Engineer (INGECON SUN 920TL X 360 Volts)

AlterPower Digos Solar, Inc.
06.2022 - 04.2025

SAP Technology Consultant

DXC Technology
03.2021 - 11.2021

Project Staff Engineer

Davao Light and Power Company
02.2019 - 07.2020

Bachelor of Science - Electrical Engineering

University of Southeastern Philippines
04.2012 - 06.2017
Roland Niñal TrañaRegistered Electrical Engineer I Registered Master Electrician I BOSH Safety Officer